Comparing the diagnostic accuracy of point-of-care lateral flow antigen testing for SARS-CoV-2 with RT-PCR in primary care (REAP-2)

  • Background: Testing for COVID-19 with quantitative reverse transcriptase-polymerase chain reaction (RT-PCR) may result in delayed detection of disease. Antigen detection via lateral flow testing (LFT) is faster and amenable to population-wide testing strategies. Our study assesses the diagnostic accuracy of LFT compared to RT-PCR on the same primarycare patients in Austria. Methods: Patients with mild to moderate flu-like symptoms attending a general practice network in an Austrian district (October 22 to November 30, 2020) received clinical assessment including LFT. All suspected COVID-19 cases obtained additional RT-PCR and were divided into two groups: Group 1 (true reactive): suspected cases with reactive LFT and positive RT-PCR; and Group 2 (false non-reactive): suspected cases with a non-reactive LFT but positive RT-PCR. Findings: Of the 2,562 symptomatic patients, 1,037 were suspected of COVID-19 and 826 (79.7%) patients tested RT-PCR positive. Among patients with positive RT-PCR, 788/826 tested LFT reactive (Group 1) and 38 (4.6%) non-reactive (Group 2). Overall sensitivity was 95.4% (95%CI: [94%,96.8%]), specificity 89.1% (95%CI: [86.3%, 91.9%]), positive predictive value 97.3% (95%CI:[95.9%, 98.7%]) and negative predictive value 82.5% (95%CI:[79.8%, 85.2%]). Reactive LFT and positive RT-PCR were positively correlated (r = 0.968,95CI=[0.952,0.985] and κ=0.823, 95%CI=[0.773,0.866]). Reactive LFT was negatively correlated with Ct-value (r = -0.2999,p < 0.001) and pre-test symptom duration (r = -0.1299,p = 0.0043) while Ct-value was positively correlated with pre-test symptom duration (r = 0.3733),p < 0.001). Interpretation: We show that LFT is an accurate alternative to RT-PCR testing in primary care. We note the importance of administering LFT properly, here combined with clinical assessment in symptomatic patients.

Download full text files

Export metadata

Metadaten
Author:Werner LeberORCiD, Oliver LammelORCiD, Andrea Siebenhofer-KroitzschORCiDGND, Monika Redlberger-FritzGND, Jasmina Panovska-GriffithsORCiD, Thomas CzypionkaORCiD
URN:urn:nbn:de:hebis:30:3-630842
DOI:https://doi.org/10.1016/j.eclinm.2021.101011
ISSN:2589-5370
Parent Title (English):EClinicalMedicine
Publisher:Elsevier
Place of publication:Amsterdam
Document Type:Article
Language:English
Date of Publication (online):2021/07/13
Date of first Publication:2021/07/13
Publishing Institution:Universitätsbibliothek Johann Christian Senckenberg
Release Date:2022/07/04
Tag:COVID-19, Primary care; Lateral flow antigen testing; Point-of-care testing; SARS-CoV-2; Sensitivity; Specificity
Volume:38.2021
Issue:art. 101011
Article Number:101011
Page Number:7
First Page:1
Last Page:7
Note:
Thomas Czypionka received funding from the European Union's Horizon 2020 Research and Innovation Programe under the grant agreement No 101016233 (PERISCOPE). No further funding was available for this study.
HeBIS-PPN:497502860
Institutes:Medizin
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Sammlungen:Universitätspublikationen
Licence (German):License LogoCreative Commons - Namensnennung 4.0