Heparin-induced thrombocytopenia in patients on extracorporeal membrane oxygenation and the role of a heparin-bonded circuit

GND
129032832
ORCID
0000-0003-0944-3273
Zugehörige Organisation
1 Heart and Vascular Institute, Penn State Health Milton S. Hershey Medical Center, Hershey, PA, USA. - 2 Center for Emergency Medicine, University Hospital Essen, Essen, Germany
Pabst, Dirk;
Zugehörige Organisation
Bon Secours Richmond Health Systems, Richmond, VA, USA
Boone, Jacqueline B.;
Zugehörige Organisation
Heart and Vascular Institute, Penn State Health Milton S. Hershey Medical Center, Hershey, PA, USA
Soleimani, Behzad;
Zugehörige Organisation
Heart and Vascular Institute, Penn State Health Milton S. Hershey Medical Center, Hershey, PA, USA
Brehm, Christoph E.

Background: In patients supported with extracorporeal membrane oxygenation, and who develop heparin-induced thrombocytopenia, there is no clear evidence to support changing to a non-heparin-coated extracorporeal membrane oxygenation circuit. Our goal was to evaluate clinical outcomes of patients who were continued on heparin-bonded circuits despite diagnosed heparin-induced thrombocytopenia.

Methods: We completed a single-center retrospective study of all patients who underwent extracorporeal membrane oxygenation support from July 2008 to July 2017 and were tested heparin-induced thrombocytopenia positive while on extracorporeal membrane oxygenation support. After diagnosis of heparin-induced thrombocytopenia, mean platelet count (k/µL) was measured on consecutive days for 14 days.

Results: Out of 455 patients, 14 (3.1%) had a diagnosis of heparin-induced thrombocytopenia by serotonin release assay and systemic heparin treatment was discontinued in every case. In total, 11 of the heparin-induced thrombocytopenia patients (78.6%) survived to discharge. The overall survival of all 455 extracorporeal membrane oxygenation patients was 54.1%. Platelets counts after discontinuation of systemic heparin in the heparin-induced thrombocytopenia patients increased from a mean of 59.8 k/µL at time of heparin-induced thrombocytopenia diagnosis to a mean of 280.2 k/µL at 14 days after discontinuation of heparin despite continuation of the heparin-bonded circuit. Platelet count increased in heparin-induced thrombocytopenia patients on extracorporeal membrane oxygenation support after discontinuation of systemic heparin even if maintained on the heparin-bonded circuit.

Conclusion: Discontinuation of systemic heparin but continuation of heparin-coated extracorporeal membrane oxygenation circuits appeared to be an appropriate response for our extracorporeal membrane oxygenation–supported patients who developed heparin-induced thrombocytopenia. Survival in this group was not significantly different to those patients on extracorporeal membrane oxygenation without heparin-induced thrombocytopenia. Larger studies should evaluate the safety of heparin-bonded extracorporeal membrane oxygenation systems in heparin-induced thrombocytopenia patients.

Zitieren

Zitierform:
Zitierform konnte nicht geladen werden.

Rechte

Rechteinhaber:

© The Author(s) 2019

Nutzung und Vervielfältigung:
Alle Rechte vorbehalten