Helmholtz Resonators with Large Aperture

  • The lowest resonant frequency of a cavity resonator is usually approximated by the classical Helmholtz formula. However, if the opening is rather large and the front wall is narrow this formula is no longer valid. Here we present a correction which is of third order in the ratio of the diameters of aperture and cavity. In addition to the high accuracy it allows to estimate the damping due to radiation. The result is found by applying the method of matched asymptotic expansions. The correction contains form factors describing the shapes of opening and cavity. They are com- puted for a number of standard geometries. Results are compared with numerical computations.

Download full text files

Export metadata

Additional Services

Search Google Scholar
Metadaten
Author:Jan Mohring
URN:urn:nbn:de:hbz:386-kluedo-7084
Series (Serial Number):Berichte des Fraunhofer-Instituts für Techno- und Wirtschaftsmathematik (ITWM Report) (10)
Document Type:Preprint
Language of publication:English
Year of Completion:1998
Year of first Publication:1998
Publishing Institution:Fraunhofer-Institut für Techno- und Wirtschaftsmathematik
Date of the Publication (Server):2000/04/03
Faculties / Organisational entities:Fraunhofer (ITWM)
DDC-Cassification:5 Naturwissenschaften und Mathematik / 510 Mathematik
Licence (German):Standard gemäß KLUEDO-Leitlinien vor dem 27.05.2011