Über die Haftkraft von adhäsiv befestigten Faserstiften nach künstlicher Alterung

Language
de
Document Type
Doctoral Thesis
Issue Date
2011-07-19
Issue Year
2011
Authors
Mackert, Tobias Andrè
Editor
Abstract

Objectives: For the restorations of endodontically treated teeth with root posts a variety of postsystems and luting agent is available. The aim of this in-vitro-study was to determine the influence of the luting system (application steps) and aging (thermocycling) to the bond strength. Materials and methods: 440 caries free human tooth roots were randomized and split in 21 groups (n= 20). The tested root posts (PhotoTech, Tech 2000 X-op, Tech 21 X-op, FRC Postec Plus, everStick Post, FiberMaster, RelyX Fiber Post, Luxa Post, DT White Post, DT Light Post SL) were used with the adhesive materials RelyX Unicem (self-adhesive resin composite) and LuxaBond/LuxaCoreZ (multistep dualcured adhesive resin composite) and inserted 13 mm deep in the root canal. For the control group, RPR Titanpost were conventionally cemented with Ketac cem. After post insertion the samples were assigned (n= 10) to the aging mode (initial: 24h waterstorage, 37°C; aging: thermocycling 40.000 cycles, 5/55°C). After embedding the root-post-samples, 5 disks (1 mm) were prepared. All disks were tested and measured on bubbles and congruency for the calculation of the bond strength surface. The bond strength was determined in a “micro-push-out-design” using a universal testing machine. The failure mode of each test body was analyzed by using a light microscope. Statistical analysis was performed using SPSS. In addition to descriptive statistics the Kruskal-Wallis-test and the Mann-Whitney-U-test were used for comparison (a= 0,05). Results: The bond strengths between the dentin-composite-post-system were influenced significantly by the luting agents (p= 0,017), the post type (p= 0,005) and incongruent canal shape (p= 0,001). The thermocycling aging (p= 0,15) and the localization in the root canal (p= 0,588) had no significant effect on the bond strength. LuxaBond/LuxaCoreZ achieved higher bond strength (14.29 ± 6.09 MPa) than RelyX Unicem (12.98 ± 5.67 MPa). The Luxa Post was the only post that showed significant differences (p= 0,005) in the multiple comparisons between all tested posts. Conclusion: The results of this in-vitro-study showed that glassfiber posts exhibited better bond strength results in combination with multistep dual-cured adhesive resin composite than with self-adhesive resin composite. The choice of the post type affected the bond strength. Glassfiber root posts achieved the highest bond strength. The influence of aging on the bond strength could not be detected.

Abstract

Hintergrund und Ziele: Für die Restauration endodontisch behandelter Zähne mit Wurzelstiften steht eine Vielfalt an Wurzelstiftsystemen und Befestigungskompositen zu Verfügung. Ziel dieser in-vitro-Studie ist es, den Einfluss des Befestigungssystems (Applikationsschritte) und der Alterung (Thermozyklische Wechselbelastung) auf die Haftkraft zu untersuchen. Material und Methode: Für die Studie wurden 420 kariesfreie menschliche Zahnwurzeln randomisiert in 21 Gruppen (n= 20) aufgeteilt. Die verwendeten Wurzelstifte (FotoTech, Tech 2000 X-op, Tech 21 X-op, FRC Postec Plus, everStick Post, FiberMaster, RelyX Fiber Post, Luxa Post, DT White Post, DT Light Post SL) wurden mit den Befestigungssystemen RelyX Unicem (selbstkonditionierender Befestigungskomposit) und LuxaBond/LuxaCoreZ (Drei-Schritt-Adhäsiv/ Befestigungskomposit) 13 mm tief im Wurzelkanal verankert. Für die Kontrollgruppe wurden RPR Titanstifte konventionell mit Ketac cem zementiert. Nach der Stiftinsertion wurden die Proben (n= 10) dem Alterungsmodus (Initial: 24h Wasserlagerung, 37°C; Alterung: Thermocycling 40.000 Zyklen, 5/55°C) zugeteilt. Aus den eingebetteten Wurzel-Stift-Proben wurden 5 Testscheiben (1 mm) präpariert. Alle Testscheiben wurden auf Blaseneinschlüsse und Kongruenz untersucht und der Stiftdurchmesser für die Berechnung der Haftflächen vermessen. Die Haftkraft wurde im „Micro-Push-out-Design“ mit Hilfe einer Universalprüfmaschine ermittelt. Der Versagens-modus jedes Prüfungskörpers wurde mittels Lichtmikroskop analysiert. Die statistische Auswertung erfolgte mittels SPSS. Neben deskriptiven Statistiken kamen der Kruskal-Wallis-Test und der Mann-Whitney-U-Test

DOI
Document's Licence
Faculties & Collections
Zugehörige ORCIDs