Longitudinal assessment of tissue properties and cardiac diffusion metrics of the ex vivo porcine heart at 7 T: Impact of continuous tissue fixation using formalin

Please always quote using this URN: urn:nbn:de:bvb:20-opus-215536
  • In this study we aimed to assess the effects of continuous formalin fixation on diffusion and relaxation metrics of the ex vivo porcine heart at 7 T. Magnetic resonance imaging was performed on eight piglet hearts using a 7 T whole body system. Hearts were measured fresh within 3 hours of cardiac arrest followed by immersion in 10% neutral buffered formalin. T\(_{2}\)* and T\(_{2}\) were assessed using a gradient multi‐echo and multi‐echo spin echo sequence, respectively. A spin echo and a custom stimulated echo sequence were employed to assessIn this study we aimed to assess the effects of continuous formalin fixation on diffusion and relaxation metrics of the ex vivo porcine heart at 7 T. Magnetic resonance imaging was performed on eight piglet hearts using a 7 T whole body system. Hearts were measured fresh within 3 hours of cardiac arrest followed by immersion in 10% neutral buffered formalin. T\(_{2}\)* and T\(_{2}\) were assessed using a gradient multi‐echo and multi‐echo spin echo sequence, respectively. A spin echo and a custom stimulated echo sequence were employed to assess diffusion time‐dependent changes in metrics of cardiac diffusion tensor imaging. SNR was determined for b = 0 images. Scans were performed for 5 mm thick apical, midcavity and basal slices (in‐plane resolution: 1 mm) and repeated 7, 15, 50, 100 and 200 days postfixation. Eigenvalues of the apparent diffusion coefficient (ADC) and fractional anisotropy (FA) decreased significantly (P < 0.05) following fixation. Relative to fresh hearts, FA values 7 and 200 days postfixation were 90% and 80%, while respective relative ADC values at those fixation stages were 78% and 92%. Statistical helix and sheetlet angle distributions as well as respective mean and median values showed no systematic influence of continuous formalin fixation. Similar to changes in the ADC, values for T\(_{2}\), T\(_{2}\)* and SNR dropped initially postfixation. Respective relative values compared with fresh hearts at day 7 were 64%, 79% and 68%, whereas continuous fixation restored T\(_{2}\), T\(_{2}\)* and SNR leading to relative values of 74%, 100%, and 81% at day 200, respectively. Relaxation parameters and diffusion metrics are significantly altered by continuous formalin fixation. The preservation of microstructure metrics following prolonged fixation is a key finding that may enable future studies of ventricular remodeling in cardiac pathologies.show moreshow less

Download full text files

Export metadata

Additional Services

Share in Twitter Search Google Scholar Statistics
Metadaten
Author: David LohrORCiD, Maxim Terekhov, Franziska Veit, Laura Maria Schreiber
URN:urn:nbn:de:bvb:20-opus-215536
Document Type:Journal article
Faculties:Medizinische Fakultät / Lehrstuhl für Tissue Engineering und Regenerative Medizin
Medizinische Fakultät / Deutsches Zentrum für Herzinsuffizienz (DZHI)
Language:English
Parent Title (English):NMR in Biomedicine
Year of Completion:2020
Volume:33
Issue:7
Article Number:e4298
Source:NMR in Biomedicine 2020, 33(7):e4298. DOI: 10.1002/nbm.4298
DOI:https://doi.org/10.1002/nbm.4298
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Tag:cardiovascular MR methods; diffusion tensor imaging; heart structure; relaxometry
Release Date:2021/06/30
Licence (German):License LogoCC BY: Creative-Commons-Lizenz: Namensnennung 4.0 International