The cement leakage in cement-augmented pedicle screw instrumentation in degenerative lumbosacral diseases: a retrospective analysis of 202 cases and 950 augmented pedicle screws

  • Original Article
  • Published:
European Spine Journal Aims and scope Submit manuscript

Abstract

Purpose

To evaluate the incidence, type and risk factors of cement leakage (CL) with cement-augmented pedicle screw instrumentation (CAPSI) in degenerative lumbosacral disease.

Methods

Two hundred and two patients using a total of 950 cement-augmented screws were enrolled. CL was classified into three types: type S: leakage via segmental veins; type B: leakage via basivertebral veins; and type I: leakage via pedicle screw instrumentation to paravertebral soft tissue. The age, gender, operation stage (primary or later stage), body mass index, bone mineral density, the number and type of augmented screw, the position of the tip of screw (lateral or internal part of vertebral body), the position of screw (left or right side), the volume of bone cement, location of the augmented vertebra (lumbar or sacrum), the type of CL and complications were recorded. Binary logistic regression correlation was used to analyze risk factors of veins leakage (type S and type B).

Results

The CL was observed in 165 patients (81.68%) and 335 screws (35.26%), leakage types of S, B and I were seen in 255 (76.12%), 77 (22.99%), and 30 (8.96%) of screws, respectively. Besides, double or multiple routes of leakage were seen in 27 screws. Number of augmented screw was a risk factor for vein leakage (OR 0.58; 95% CI 0.44–0.77; P = 0.000). Furthermore, the doses of cement (OR 0.79; 95% CI 0.61–0.99; P = 0.038) and the position of screw (OR 0.39; 95% CI 0.29–0.53; P = 0.000) were identified as risk factors for type S, and the doses of bone cement (OR 0.37; 95% CI 0.25–0.54; P = 0.000) and the position of the tip of screw (OR 0.07; 95% CI 0.04–0.13; P = 0.000) were risk factors for type B.

Conclusions

CAPSI bears a high risk of asymptomatic CL, with a higher rate of leakage into segmental veins and basivertebral veins. As is known, more augmented screws and larger doses of cement are risk factors for veins leakage (type S and type B), while the tip of screw approaching to the midline of the vertebral body is another risk factor to type B. Thus, the CL could be reduced by the amelioration of operative techniques and procedures.

Graphical abstract

These slides can be retrieved under Electronic Supplementary Material.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. Keorochana G, Pairuchvej S, Trathitephun W, Arirachakaran A, Predeeprompan P, Kongtharvonskul J (2017) Comparative outcomes of cortical screw trajectory fixation and pedicle screw fixation in lumbar spinal fusion: systematic review and meta-analysis. World Neurosurg 102:340–349

    Article  PubMed  Google Scholar 

  2. Lykissas MG, Jain VV, Nathan ST, Pawar V, Eismann EA, Sturm PF et al (2013) Mid- to long-term outcomes in adolescent idiopathic scoliosis after instrumented posterior spinal fusion: a meta-analysis. Spine (Phila Pa 1976) 38(2):E113–E119

    Article  Google Scholar 

  3. Hoppe S, Keel MJB (2017) Pedicle screw augmentation in osteoporotic spine: indications, limitations and technical aspects. Eur J Trauma Emerg Surg 43(1):3–8

    Article  CAS  PubMed  Google Scholar 

  4. Halvorson TL, Kelley LA, Thomas KA, Whitecloud TS, Cook SD (1994) Effects of bone mineral density on pedicle screw fixation. Spine (Phila Pa 1976) 19(21):2415–2420

    Article  CAS  Google Scholar 

  5. Ramaswamy R, Evans S, Kosashvili Y (2010) Holding power of variable pitch screws in osteoporotic, osteopenic and normal bone: are all screws created equal. Injury 41(2):179–183

    Article  PubMed  Google Scholar 

  6. Choma TJ, Pfeiffer FM, Swope RW, Hirner JP (2012) Pedicle screw design and cement augmentation in osteoporotic vertebrae: effects of fenestrations and cement viscosity on fixation and extraction. Spine (Phila Pa 1976) 37(26):E1628–E1632

    Article  Google Scholar 

  7. Chang MC, Kao HC, Ying SH, Liu CL (2013) Polymethylmethacrylate augmentation of cannulated pedicle screws for fixation in osteoporotic spines and comparison of its clinical results and biomechanical characteristics with the needle injection method. J Spinal Disord Tech 26(6):305–315

    Article  PubMed  Google Scholar 

  8. Moussazadeh N, Rubin DG, McLaughlin L, Lis E, Bilsky MH, Laufer I (2015) Short-segment percutaneous pedicle screw fixation with cement augmentation for tumor-induced spinal instability. Spine J 15(7):1609–1617

    Article  PubMed  Google Scholar 

  9. Elder BD, Lo SF, Holmes C, Goodwin CR et al (2015) The biomechanics of pedicle screw augmentation with cement. Spine J 15(6):1432–1445

    Article  PubMed  Google Scholar 

  10. Mueller JU, Baldauf J, Marx S, Kirsch M, Schroeder HW, Pillich DT (2016) Cement leakage in pedicle screw augmentation: a prospective analysis of 98 patients and 474 augmented pedicle screws. J Neurosurg Spine 25(1):103–109

    Article  PubMed  Google Scholar 

  11. Martín-Fernández M, López-Herradón A, Piñera AR, Tomé-Bermejo F et al (2017) Potential risks of using cement-augmented screws for spinal fusion in patients with low bone quality. Spine J 17(8):1192–1199

    Article  PubMed  Google Scholar 

  12. Röllinghoff M, Siewe J, Eysel P, Delank KS (2010) Pulmonary cement embolism after augmentation of pedicle screws with bone cement. Acta Orthop Belg 76(2):269–273

    PubMed  Google Scholar 

  13. Yeom JS, Kim WJ, Choy WS, Lee CK, Chang BS, Kang JW (2003) Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures. J Bone Joint Surg Br 85(1):83–89

    Article  CAS  PubMed  Google Scholar 

  14. Kerry G, Ruedinger C, Steiner HH (2013) Cement embolism into the venous system after pedicle screw fixation: case report, literature review, and prevention tips. Orthop Rev (Pavia) 5(3):e24

    Article  Google Scholar 

  15. Ding J, Zhang Q, Zhu J, Tao W et al (2016) Risk factors for predicting cement leakage following percutaneous vertebroplasty for osteoporotic vertebral compression fractures. Eur Spine J 25(11):3411–3417

    Article  PubMed  Google Scholar 

  16. Arabmotlagh M, Rickert M, Lukas A, Rauschmann M, Fleege C (2017) Small cavity creation in the vertebral body reduces the rate of cement leakage during vertebroplasty. J Orthop Res 35(1):154–159

    Article  CAS  PubMed  Google Scholar 

  17. Zhan Y, Jiang J, Liao H, Tan H, Yang K (2017) Risk factors for cement leakage after vertebroplasty or kyphoplasty: a meta-analysis of published evidence. World Neurosurg 101:633–642

    Article  PubMed  Google Scholar 

  18. Galbusera F, Volkheimer D, Reitmaier S, Berger-Roscher N, Kienle A, Wilke HJ (2015) Pedicle screw loosening: a clinically relevant complication. Eur Spine J 24(5):1005–1016

    Article  PubMed  Google Scholar 

  19. Chen YL, Chen WC, Chou CW, Chen JW et al (2014) Biomechanical study of expandable pedicle screw fixation in severe osteoporotic bone comparing with conventional and cement-augmented pedicle screws. Med Eng Phys 36(11):1416–1420

    Article  PubMed  Google Scholar 

  20. Nakashima H, Kawakami N, Tsuji T, Ohara T et al (2015) Adjacent segment disease after posterior lumbar interbody fusion: based on cases with a minimum of 10 years of follow-up. Spine (Phila Pa 1976) 40(14):E831–E841

    Article  Google Scholar 

  21. Gazzeri R, Roperto R, Fiore C (2016) Surgical treatment of degenerative and traumatic spinal diseases with expandable screws in patients with osteoporosis: 2-year follow-up clinical study. J Neurosurg Spine 25(5):610–619

    Article  PubMed  Google Scholar 

  22. Bullmann V, Liljenqvist UR, Rödl R, Schulte TL (2010) Pedicle screw augmentation from a biomechanical perspective. Orthopade 39(7):673–678

    Article  CAS  PubMed  Google Scholar 

  23. Tan JS, Bailey CS, Dvorak MF, Fisher CG, Cripton PA, Oxland TR (2007) Cement augmentation of vertebral screws enhances the interface strength between interbody device and vertebral body. Spine (Phila Pa 1976) 32(3):334–341

    Article  Google Scholar 

  24. Janssen I, Ryang YM, Gempt J, Bette S et al (2017) Risk of cement leakage and pulmonary embolism by bone cement-augmented pedicle screw fixation of the thoracolumbar spine. Spine J 17(6):837–844

    Article  PubMed  Google Scholar 

  25. Hatzantonis C, Czyz M, Pyzik R, Boszczyk BM (2017) Intracardiac bone cement embolism as a complication of vertebroplasty: management strategy. Eur Spine J 26(12):3199–3205

    Article  PubMed  Google Scholar 

  26. Audat ZA, Alfawareh MD, Darwish FT, Alomari AA (2016) Intracardiac leakage of cement during kyphoplasty and vertebroplasty: a case report. Am J Case Rep 17:326–330

    Article  PubMed  PubMed Central  Google Scholar 

  27. El SA, Kelm A, Meier S, Sander AL et al (2013) Intraoperative PEEP-ventilation during PMMA-injection for augmented pedicle screws: improvement of leakage rate in spinal surgery. Eur J Trauma Emerg Surg 39(5):461–468

    Article  Google Scholar 

  28. Zhu SY, Zhong ZM, Wu Q, Chen JT (2016) Risk factors for bone cement leakage in percutaneous vertebroplasty: a retrospective study of four hundred and eighty five patients. Int Orthop 40(6):1205–1210

    Article  PubMed  Google Scholar 

  29. Fölsch C, Goost H, Figiel J, Paletta JR, Schultz W, Lakemeier S (2012) Correlation of pull-out strength of cement-augmented pedicle screws with CT-volumetric measurement of cement. Biomed Tech (Berl) 57(6):473–480

    Article  Google Scholar 

  30. Bokov A, Mlyavykh S, Aleynik A, Kutlaeva M, Anderson G (2016) The potential impact of venobasillar system morphology and applied technique on epidural cement leakage with percutaneous vertebroplasty. Pain Physician 19(6):357–362

    PubMed  Google Scholar 

  31. Kasó G, Horváth Z, Szenohradszky K, Sándor J, Dóczi T (2008) Comparison of CT characteristics of extravertebral cement leakages after vertebroplasty performed by different navigation and injection techniques. Acta Neurochir (Wien) 150(7):677–683 (discussion 683)

    Article  Google Scholar 

  32. Tajsic T, Patel K, Farmer R, Mannion RJ, Trivedi RA (2018) Spinal navigation for minimally invasive thoracic and lumbosacral spine fixation: implications for radiation exposure, operative time, and accuracy of pedicle screw placement. Eur Spine J 27(8):1918–1924

    Article  CAS  PubMed  Google Scholar 

  33. Kafchitsas K, Geiger F, Rauschmann M, Schmidt S (2010) Cement distribution in vertebroplasty pedicle screws with different designs. Orthopade 39(7):679–686

    Article  CAS  PubMed  Google Scholar 

  34. Loeffel M, Ferguson SJ, Nolte LP, Kowal JH (2008) Vertebroplasty: experimental characterization of polymethylmethacrylate bone cement spreading as a function of viscosity, bone porosity, and flow rate. Spine (Phila Pa 1976) 33(12):1352–1359

    Article  Google Scholar 

Download references

Acknowledgements

This study supported by the Guangzhou Science and Technology Project (201707010460), Guangdong Science and Technology Project (2016A020215137). The funders had no role in study design, data collection or analysis, decision to publish, or preparation of the manuscript.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Shun-cong Zhang.

Ethics declarations

Conflict of interest

The authors declare that there are no conflicts of interest regarding this work.

Ethical approval

This study has been reviewed by the appropriate ethics committee of The First Affiliated Hospital of Guangzhou University of Chinese Medicine and performed in accordance with the ethical standards laid down in an appropriate version of the 1964 Declaration of Helsinki.

Informed consent

All patients gave their informed consent prior to their inclusion in the study.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Electronic supplementary material

Below is the link to the electronic supplementary material.

Supplementary material 1 (PPTX 227 kb)

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Guo, Hz., Tang, Yc., Guo, Dq. et al. The cement leakage in cement-augmented pedicle screw instrumentation in degenerative lumbosacral diseases: a retrospective analysis of 202 cases and 950 augmented pedicle screws. Eur Spine J 28, 1661–1669 (2019). https://doi.org/10.1007/s00586-019-05985-4

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00586-019-05985-4

Keywords

Navigation