Repositionable Versus Balloon-Expandable Devices for Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis.

Details

Ressource 1Download: e004088.full.pdf (1437.80 [Ko])
State: Public
Version: Final published version
Serval ID
serval:BIB_F5C5038B6EE1
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Repositionable Versus Balloon-Expandable Devices for Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis.
Journal
Journal of the American Heart Association
Author(s)
Pilgrim T., Stortecky S., Nietlispach F., Heg D., Tueller D., Toggweiler S., Ferrari E., Noble S., Maisano F., Jeger R., Roffi M., Grünenfelder J., Huber C., Wenaweser P., Windecker S.
ISSN
2047-9980 (Electronic)
ISSN-L
2047-9980
Publication state
Published
Issued date
17/11/2016
Peer-reviewed
Oui
Volume
5
Number
11
Pages
1-10
Language
english
Notes
Publication types: Comparative Study ; Journal Article
Publication Status: epublish
Abstract
The safety and effectiveness of the fully repositionable LOTUS valve system as compared with the balloon-expandable Edwards SAPIEN 3 prosthesis for the treatment of aortic stenosis has not been evaluated to date.
All patients undergoing transcatheter aortic valve implantation with the Edwards SAPIEN 3 or the LOTUS valve system were included into the Swiss Transcatheter Aortic Valve Implantation Registry. An adjusted analysis was performed to compare the early clinical safety outcome according to the Valve Academic Research Consortium-2 definition. Between February 2014 and September 2015, 140 and 815 patients were treated with the LOTUS and the Edwards SAPIEN 3 valve, respectively. There was no difference in crude and adjusted analyses of the early safety outcome between patients treated with LOTUS (14.3%) and those treated with Edwards SAPIEN 3 (14.6%) (crude hazard ratio, 0.97; 95% CI, 0.61-1.56 [P=0.915]; adjusted hazard ratio, 1.03; 95% CI, 0.64-1.67 [P=0.909]). More than mild aortic regurgitation was <2% for both devices. A total of 34.3% of patients treated with LOTUS and 14.1% of patients treated with Edwards SAPIEN 3 required a permanent pacemaker (HR, 2.76; 95% CI, 1.97-3.87 [P<0.001]).
The repositionable LOTUS valve system and the balloon-expandable Edwards SAPIEN 3 prosthesis appeared comparable in regard to the Valve Academic Research Consortium-2 early safety outcome, and the rates of more than mild aortic regurgitation were exceedingly low for both devices. The need for new permanent pacemaker implantation was more frequent among patients treated with the LOTUS valve.

Keywords
Aged, Aged, 80 and over, Aortic Valve Insufficiency/epidemiology, Aortic Valve Stenosis/surgery, Cohort Studies, Female, Heart Valve Prosthesis, Humans, Male, Postoperative Complications/epidemiology, Proportional Hazards Models, Prospective Studies, Prosthesis Design, Registries, Switzerland/epidemiology, Transcatheter Aortic Valve Replacement/instrumentation, aortic valve regurgitation, newer‐generation devices, permanent pacemaker, transcatheter aortic valve replacement
Pubmed
Web of science
Open Access
Yes
Create date
28/11/2016 15:08
Last modification date
20/08/2019 17:22
Usage data