A systematic multi-technique comparison of luminescence characteristics of two reference quartz samples

Details

Ressource 1Download: Schmidt2022a.pdf (5567.75 [Ko])
State: Public
Version: Final published version
License: CC BY-NC-ND 4.0
Serval ID
serval:BIB_EE830155ECDB
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
A systematic multi-technique comparison of luminescence characteristics of two reference quartz samples
Journal
Journal of Luminescence
Author(s)
Schmidt Christoph, Chruścińska Alicja, Fasoli Mauro, Biernacka Magdalena, Kreutzer Sebastian, Polymeris Georgios S., Sanderson David C.W., Cresswell Alan, Adamiec Grzegorz, Martini Marco
ISSN
0022-2313
Publication state
Published
Issued date
10/2022
Peer-reviewed
Oui
Volume
250
Pages
119070
Language
english
Abstract
Further developments in luminescence dating, dosimetry and temperature-sensing require a deep understanding of luminescence processes and their driving parameters. Natural quartz is one of the most widely used minerals for these purposes. Still, poor reproducibility of results often hampers comparability and credibility from findings in the literature. We identified the lack of suitable natural reference samples as a pivotal problem impeding significant progression. Ideally, basic investigations involve several laboratories working on well-characterised reference quartz samples with different characteristics. Investigations should include multiple complementing methods to analyse luminescence properties and mineralogical and geochemical composition.
Here, we present such a multi-technique luminescence comparison of two natural quartz samples. Next to the recently introduced Fontainebleau (FB) reference quartz, we propose another reference sample derived from the ‘Silver Sands of Morar’ (lab code ‘MR’; Scotland, UK). Our experiments confirm that both quartz samples behave fundamentally different in terms of signal composition and sensitivity. The comparative characterisation of both samples targeted electron traps via thermoluminescence (TL) and optically stimulated luminescence (OSL) techniques and luminescence centres via radioluminescence and time-resolved OSL spectrometry. In summary, we conclude that all observed differences are likely the results of divergent defect concentrations rather than variances in defects' composition (nature). The measurement data of our study are accessible open-access for inspection by others.
Keywords
Luminescence dating, Quartz, Reference samples, TL, OSL, LM-OSL, TM-OSL, RL, TR-OSL
Open Access
Yes
Create date
29/07/2022 8:29
Last modification date
16/12/2022 7:51
Usage data