Probe-based confocal laser endomicroscopy and fluorescence-based enhanced reality for real-time assessment of intestinal microcirculation in a porcine model of sigmoid ischemia.

Details

Ressource 1Download: 31.pdf (1438.21 [Ko])
State: Public
Version: Final published version
License: Not specified
It was possible to publish this article open access thanks to a Swiss National Licence with the publisher.
Serval ID
serval:BIB_9B6FCF8829B2
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Probe-based confocal laser endomicroscopy and fluorescence-based enhanced reality for real-time assessment of intestinal microcirculation in a porcine model of sigmoid ischemia.
Journal
Surgical endoscopy
Author(s)
Diana M., Dallemagne B., Chung H., Nagao Y., Halvax P., Agnus V., Soler L., Lindner V., Demartines N., Diemunsch P., Geny B., Swanström L., Marescaux J.
ISSN
1432-2218 (Electronic)
ISSN-L
0930-2794
Publication state
Published
Issued date
11/2014
Peer-reviewed
Oui
Volume
28
Number
11
Pages
3224-3233
Language
english
Notes
Publication types: Journal Article ; Research Support, Non-U.S. Gov't
Publication Status: ppublish
Abstract
Surgeons currently rely on visual clues to estimate the presence of sufficient vascularity for safe anastomosis. We aimed to assess the accuracy of endoluminal confocal laser endomicroscopy (CLE) and laparoscopic fluorescence-based enhanced reality (FLER), using near-infrared imaging and fluorescence from injected Indocyanine Green, to identify the transition from ischemic to vascular areas in a porcine model of mesenteric ischemia.
Six pigs underwent 1-h sigmoid segmental ischemia. The ischemic area was evaluated by clinical assessment and FLER to determine presumed viable margins. For each sigmoid colon, 5 regions of interest (ROIs) were identified: ischemic (ROI 1), presumed viable margins ROI 2a (distal) and 2b (proximal), and vascular areas 3a (distal) and 3b (proximal). After injection of fluorescein, CLE scanning of the mucosa from the ischemic area toward viable margins was performed. Capillary blood samples were obtained by puncturing the serosa at the ROIs, and capillary lactates were measured with the EDGE(®) analyzer.
Capillary lactates were significantly higher at ROI 1 (4.91 mmol/L) when compared to resection margins (2.8 mmol/L; mean difference: 2.11; p < 0.05) identified by FLER. There was no significant difference in lactates between ROI1 and resection margins identified by clinical evaluation. In 50 % of cases, ROI 2aCLINIC-2bCLINIC were considered to match (<1 cm distance) with ROI 2aFLER-2bFLER. Confocal analysis revealed specific clues to identify the transition from ischemic to viable areas corresponding to those assessed by FLER in 11/12 cases versus 7/12 for those identified by clinical evaluation.
In this experimental model, FLER and CLE were more accurate than clinical evaluation to delineate bowel vascularization.
Keywords
Animals, Colon, Sigmoid/blood supply, Coloring Agents, Disease Models, Animal, Image Enhancement/methods, Indocyanine Green, Ischemia/diagnosis, Ischemia/physiopathology, Microcirculation/physiology, Microscopy, Confocal/methods, Reproducibility of Results, Swine
Pubmed
Web of science
Create date
28/07/2021 9:24
Last modification date
09/09/2021 6:12
Usage data