Percutaneous Valvular Closure Followed by TAV-in-TAV Intervention during a Single Procedure in order to Treat a Severe Paravalvular Leak after Performing TAVI in a Bicuspid Aortic Stenosis.

Details

Ressource 1Download: 31149362_BIB_506E30995E70.pdf (3144.53 [Ko])
State: Public
Version: Final published version
License: CC BY 4.0
Serval ID
serval:BIB_506E30995E70
Type
Article: article from journal or magazin.
Publication sub-type
Case report (case report): feedback on an observation with a short commentary.
Collection
Publications
Institution
Title
Percutaneous Valvular Closure Followed by TAV-in-TAV Intervention during a Single Procedure in order to Treat a Severe Paravalvular Leak after Performing TAVI in a Bicuspid Aortic Stenosis.
Journal
Case reports in cardiology
Author(s)
Tzimas G., Eeckhout E., Antiochos P., Roguelov C., Fournier S., Harbaoui B., Monney P., Muller O.
ISSN
2090-6404 (Print)
ISSN-L
2090-6404
Publication state
Published
Issued date
2019
Peer-reviewed
Oui
Volume
2019
Pages
4825607
Language
english
Notes
Publication types: Case Reports
Publication Status: epublish
Abstract
In an era where transcatheter aortic valve implantation (TAVI) indications and utilization are expanding beyond high-risk patients, paravalvular leak remains the intervention's Achilles heel. Effective reduction of paravalvular leak is important in order to ensure an optimal clinical outcome. We present here the first case report in which percutaneous valvular closure using Amplatzer plugs followed by a TAV-in-TAV intervention during the same procedure managed to resolve a severe paravalvular leak with haemodynamic instability, after TAVI for a bicuspid aortic stenosis.
Pubmed
Web of science
Open Access
Yes
Create date
18/06/2019 17:08
Last modification date
15/01/2021 8:09
Usage data