Titel: Combined biomechanical and tomographic keratoconus staging: Adding a biomechanical parameter to the ABCD keratoconus staging system
VerfasserIn: Flockerzi, Elias
Vinciguerra, Riccardo
Belin, Michael Wellington
Vinciguerra, Paolo
Ambrósio, Renato
Seitz, Berthold
Sprache: Englisch
Titel: Acta Ophthalmologica
Bandnummer: 100
Heft: 5
Seiten: e1135-e1142
Verlag/Plattform: Wiley
Erscheinungsjahr: 2022
Freie Schlagwörter: ABCD grading
biomechanics
Corvis Biomechanical Index
correlation
Corvis
keratoconus
tomography
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Purpose This retrospective cross-sectional study evaluated the potential of an additional biomechanical parameter ‘E’ as an addition to the tomographic ABCD ectasia/keratoconus (KC) staging. Methods The Corvis Biomechanical Factor (CBiF) represents the modified linear term of the Corvis Biomechanical Index (CBI) developed based on 448 KC corneas from the Homburg Keratoconus Center (HKC). The CBiF range was divided into five stages (E0 to E4) to create a grading system according to the ABCD stages. Stage E0 was characterized by values smaller than the 2.5 percentile. The thresholds were created by dividing the CBiF range between the 2.5 and 97.5 percentiles into four groups of equal values (E1–E4). The frequency distribution of ‘E’ was analysed and independently validated based on another 860 KC corneas dataset from Milano and Rio de Janeiro (MR). The relationship between ‘E’ and the ABCD staging was analysed by cross-tabulation. The specificity of ‘E’ was assessed based on healthy controls (112|851) from both datasets (HKC|MR). Results ‘E’ was normally distributed with E0 = 37|30, E1 = 86|200, E2 = 155|354, E3 = 101|206, E4 = 69|70 in the KC group and 96.4%|90.5% of the controls classified E0 in the HKC|MR dataset, respectively. Cross-tabulation revealed that ‘E’ was most comparable to posterior corneal curvature (‘B’) in both datasets, while showing a trend towards more advanced stages in comparison to anterior corneal curvature (‘A’) and thinnest corneal thickness (‘C’). Conclusion The novel Corvis-derived parameter ‘E’ provides a biomechanical staging for ectasia/KC potentially enhancing the ABCD staging and may detect abnormalities before tomographic changes, which requires further studies.
DOI der Erstveröffentlichung: 10.1111/aos.15044
URL der Erstveröffentlichung: https://onlinelibrary.wiley.com/doi/10.1111/aos.15044
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-368558
hdl:20.500.11880/33485
http://dx.doi.org/10.22028/D291-36855
ISSN: 1755-3768
1755-375X
Datum des Eintrags: 18-Jul-2022
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Augenheilkunde
Professur: M - Prof. Dr. Berthold Seitz
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes



Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons