Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen: doi:10.22028/D291-33210
Titel: Novel, vessel anatomy adjusting drug-coated balloon-Preclinical evaluation in peripheral porcine arteries
VerfasserIn: Bienek, Stephanie
Kusmierczuk, Maciej
Mittag, Antje
Bettink, Stephanie
Scheller, Bruno
Sprache: Englisch
Titel: Catheterization and Cardiovascular Interventions
Bandnummer: 95
Heft: 2
Seiten: 319–328
Verlag/Plattform: Wiley
Erscheinungsjahr: 2019
Freie Schlagwörter: drug transfer
inhibition of neointimal proliferation
vessel anatomy adjusting drug-coated balloon
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: The diameter of balloons or stents is selected according to the estimated reference vessel diameter and do not adapt to the vessel anatomy. The aim of the present preclinical studies was to investigate a novel, vessel anatomy adjusting hypercompliant drug-coated balloon catheter (HCDCB).Methods Hypercompliant balloon membranes were coated in a constricted state with high drug density. Drug adherence was investigated in vitro, transfer to the porcine peripheral arteries and longitudinal distribution in vivo. In young domestic swine, neointimal proliferation was induced by vessel overstretch and continuous irritation by permanent stents. Uncoated hypercompliant balloons (HCB), and standard uncoated balloons and drug‐coated balloons (DCB) served as controls. Efficacy was assessed by angiography, optical coherence tomography (OCT), and histomorphometry. Results HCDCB lost 18.0 ± 3.9% of dose during in vitro simulated delivery to the lesion. Drug transfer to the vessel wall was 13.9 ± 6.4% and drug concentration was 1,044 ± 529 ng/mg tissue. Four weeks after treatment, the histomorphometric neointimal area was smaller with HCDCB versus uncoated HCB (2.39 ± 0.55 mm2 vs. 3.26 ± 0.72 mm2, p = .038) and area stenosis (OCT) was less (11.6 ± 6.9% vs. 24.7 ± 9.7%, p = .022). No premature death occurred and no in‐life clinical symptoms or treatment‐associated thrombi were observed. Conclusions HCDCB were found to inhibit excessive neointimal proliferation. Balloon adaption to different vessel diameters and shapes may provide drug‐delivery in irregular lumen and facilitate balloon selection.
DOI der Erstveröffentlichung: 10.1002/ccd.28592
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-332106
hdl:20.500.11880/30554
http://dx.doi.org/10.22028/D291-33210
ISSN: 1522-726X
1522-1946
Datum des Eintrags: 4-Feb-2021
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Innere Medizin
Professur: M - Keiner Professur zugeordnet
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
ccd.28592.pdf1,72 MBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons