Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen: doi:10.22028/D291-27427
Titel: Eye-Tracker-Guided Non-Mechanical Excimer Laser Assisted Penetrating Keratoplasty
VerfasserIn: Janunts, Edgar
Schirra, Frank
Szentmáry, Nora
Seitz, Berthold
Langenbucher, Achim
Sprache: Englisch
Titel: Sensors
Bandnummer: 13
Heft: 3
Startseite: 3753
Endseite: 3764
Verlag/Plattform: MDPI
Erscheinungsjahr: 2013
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Purpose: The purpose of the study was to implement a new eye tracking mask which could be used to guide the laser beam in automated non-mechanical excimer laser assisted penetrating keratoplasty. Materials and methods: A new trephination mask design with an elevated surface geometry has been proposed with a step formation between conical and flat interfaces. Two recipient masks of 7.5/8.0 mm have been manufactured and tested. The masks have outer diameter of 12.5 mm, step formation at 10.5 mm, and slope of conical surfaces 15°. Its functionality has been tested in different lateral positions and tilts on a planar surface, and pig eye experiments. After successful validation on porcine eyes, new masks have been produced and tested on two patients. Results: The build-in eye tracking software of the MEL 70 was always able to capture the masks. It has been shown that the unwanted pigmentation/pattern induced by the laser pulses on the mask surface does not influence the eye-tracking efficiency. The masks could be tracked within the 18 × 14 mm lateral displacement and up to 12° tilt. Two patient cases are demonstrated. No complications were observed during the surgery, although it needs some attention for aligning the mask horizontally before trephination. Stability of eye tracking masks is emphasized by inducing on purpose movements of the patient head. Conclusion: Eye-tracking-guided penetrating keratoplasty was successfully applied in clinical practice, which enables robust tracking criteria within an extended range. It facilitates the automated trephination procedure of excimer laser-assisted penetrating keratoplasty.
DOI der Erstveröffentlichung: 10.3390/s130303753
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-274270
hdl:20.500.11880/28522
http://dx.doi.org/10.22028/D291-27427
ISSN: 1424-8220
Datum des Eintrags: 3-Jan-2020
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Augenheilkunde
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
sensors-13-03753.pdf2,78 MBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons