KIT | KIT-Bibliothek | Impressum | Datenschutz

Numerical Calculation of Specific Energy Distribution of I-125 in Water with Geant4, Using Different Frequency Distributions

Heide, Bernd ORCID iD icon

Abstract:

The specific energy distributions in water caused by I-125 atoms, located in the centre of a sphere with a radius of 5 μm, were calculated using geant4. The dependence of the specific energy on the respective electron frequency distributions was investigated, since there has been a lack of knowledge of the explicit electron frequency distribution up to now. The electron frequency distribution was modelled as Poisson, log-normal, or uniform distribution. Among others, some differences in the specific energy distribution were found. The lowest average specific energy, however, was within the range of the highest average specific energy and vice versa.


Volltext §
DOI: 10.5445/IR/1000076128
Cover der Publikation
Zugehörige Institution(en) am KIT Institut für Nukleare Entsorgung (INE)
Publikationstyp Forschungsbericht/Preprint
Publikationsdatum 27.10.2017
Sprache Englisch
Identifikator ISSN: 2194-1629
urn:nbn:de:swb:90-761286
KITopen-ID: 1000076128
HGF-Programm 32.01.16 (POF III, LK 01) Strahlenschutzforschung
Verlag Karlsruher Institut für Technologie (KIT)
Umfang 13 S.
Serie KIT Scientific Working Papers ; 71
KIT – Die Forschungsuniversität in der Helmholtz-Gemeinschaft