Mechanical circulatory support for destination therapy.

Details

Ressource 1Download: 26945160.pdf (1104.27 [Ko])
State: Public
Version: Final published version
Serval ID
serval:BIB_9A180CF59DE7
Type
Article: article from journal or magazin.
Publication sub-type
Review (review): journal as complete as possible of one specific subject, written based on exhaustive analyses from published work.
Collection
Publications
Institution
Title
Mechanical circulatory support for destination therapy.
Journal
Swiss Medical Weekly
Author(s)
Tozzi P., Hullin R.
ISSN
1424-3997 (Electronic)
ISSN-L
0036-7672
Publication state
Published
Issued date
2016
Peer-reviewed
Oui
Volume
146
Pages
w14267
Language
english
Notes
Publication types: Journal Article
Publication Status: epublish
Abstract
Patients with chronic heart failure who are not eligible for heart transplant and whose life expectancy depends mainly on the heart disease may benefit from mechanical circulatory support. Mechanical circulatory support restores adequate cardiac output and organ perfusion and eventually improves patients' clinical condition, quality of life and life expectancy. This treatment is called destination therapy (DT) and we estimate that in Switzerland more than 120 patients per year could benefit from it. In the last 10 years, design of the devices, implantation techniques and prognoses have changed dramatically. The key to successful therapy with a left ventricular assist device is appropriate patient selection, although we are still working on the definition of reliable inclusion and exclusion criteria and optimal timing for surgical implantation. Devices providing best long-term results are continuous flow, rotary or axial blood pumps implanted using minimally invasive techniques on a beating heart. These new devices (Thoratec HeartMate II and HeartWare HVAD) have only a single moving part, and have improved durability with virtually 10 years freedom from mechanical failure. In selected patients, the overall actuarial survival of DT patients is 75% at 1 year and 62% at 2 years, with a clear improvement in quality of life compared with medical management only. Complications include bleeding and infections; their overall incidence is significantly lower than with previous devices and their management is well defined. DT is evolving into an effective and reasonably cost-effective treatment option for a growing population of patients not eligible for heart transplant, showing encouraging survival rates at 2 years and providing clear improvement in quality of life. The future is bright for people suffering from chronic heart failure.
Pubmed
Web of science
Open Access
Yes
Create date
10/03/2016 19:26
Last modification date
20/08/2019 16:01
Usage data